Jumper man Tech
チャンネル登録者数 11.2万人
12万 回視聴 ・ 3781いいね ・ 2021/01/13
HVAC: How To Test a Single Phase Compressor & Check For Any Grounds (Insulation Resistance) Ohm Test
How to check a compressor for any grounds
How to check the windings of a single phase compressor
How to check resistance of a single phase compressor
How to ohm out a compressor
How to read ohms on a compressor
How to check the windings of a refrigeration compressor
How to test for bad compressor. Ohms test with multimeter
Troubleshoot a grounded (Shorted to ground) compressor
How to test a compressor - HVAC
How to test a refrigeration compressor
How to troubleshoot a 3 phase compressor using a muli-meter
How to check the windings of a 3 phase compressor
How to check resistance of a 3 phase compressor
Single phase vs three phase
Fluke 902 FC HVAC True-RMS Clamp Meter
https://amzn.to/39wvwiK
Veto Pro Pac TECH-LC Tool Bag
https://amzn.to/3qbmIWg
hvac,hvacr,ac,3 phase compressor troubleshooting,3 phase compressor,3 phase,resistance,ohms,how to check 3 phase compressor,how to check 3 phase compressor windings,how to check compressor hvac,how to check compressor on refrigerator,how to check compressor for,how to check for bad compressor hvac,how to check resistance on compressor,how to ohm out a compressor,how to check for a grounded compressor,how to test 3 phase compressor winding,3 phase compressor testing
Thanks for watching!
Email: Jumpermantech@Gmail.com
Follow me on instagram! @JumpRmantech
コメント
関連動画

HVAC Training: How To Check A 3 Phase Inverter Compressor (DC Compressor Troubleshooting) Testing
46,739 回視聴 - 1 年前

How To Troubleshoot 3 Phase Motor With A MultiMeter (3 Phase Motor Test) Winding Resistance Test Ohm
292,061 回視聴 - 4 年前

Testing if an HVACR Compressor is Shorted to Ground, Open, or Overload Tripped!
802,333 回視聴 - 4 年前

HVACR: General Purpose Switching Relays EXPLAINED (How It Works) Everything You Need To Know! 903
19,839 回視聴 - 3 年前

HVAC TRAINING BOARD: How To Bypass A Thermostat (How To Jump Out A Thermostat) Troubleshooting Tips
87,802 回視聴 - 3 年前

How to check your Electrical motor winding - Continuity & Insulation resistance test
285,437 回視聴 - 3 年前

HVAC Training Board: How To Troubleshoot A Contactor (Electrical Training Board/2 Pole Contactors)
126,902 回視聴 - 3 年前

HVAC Training: HVAC Unit Overview/Tutorial (Packaged Air Conditioner W/Inline Duct Furnace)
15,502 回視聴 - 4 年前

HVACR: "Megger" Insulation Test For 3 Phase Compressor (Motor Windings Insulation Test) SUPCO M500
30,661 回視聴 - 3 年前
再生方法の変更
動画のデフォルトの再生方法を設定できます。埋め込みで見れるなら埋め込みで見た方が良いですよ。